Series
477
|
Handheld Digital Manometer
|
|
|
Selectable
Pressure Units, +/-0.5% Accuracy, FM Approved Intrinsically
|
|
|
Safe
for Hazardous Locations, Class 1, Div.1, Group A, B, C, D, T4
|
|
|
New Low Pressure
Ranges
|
|
|
USB
Option Comes with Cable and Software for Easy Data Downloading.
|
|
|
Instant
Selection from up to Nine English/Metric Units.
|
|
|
Stores 40 Readings in Memory for
Later Reference.
|
|
|
Measure
Positive, Negative or Differential Pressures.
|
|
|
Large
Easy-to-Read 0.4” LCD Display Includes
Switchable Backlight for Great Visibility
--- Anywhere!
|
|
|
Both
Audible and Visual Overpressure Alarms.
|
|
|
Includes +
and – Indicators plus Low Battery Warning.
|
|
|
Operates up to 100
Hours on a Single 9 Volt Battery.
|
|
|
SPECIFICATIONS
|
|
|
Service: Air and compatible
gases. FM models air and compatible combustible gases.
|
|
Wetted Materials: Consult factory.
|
|
Accuracy: +/-0.5% F.S., 60 to 78๐F (15.6 to 25.6๐C); +/-1.5% F.S. from
32 to 60๐F and
78
to 104๐F (0 to 15.6๐C and 25.6 to 40๐C).
|
|
Pressure Hysteresis: +/-0.1%
of full scale.
|
|
Temperature
Limits:
0 to 140๐F (-17.8 to 60๐C).
|
|
Compensated Temperature Limits: 32 to 104๐F (-0 to 40๐C).
|
|
Storage
Temperature Limits:
-4 to 176๐F (-20 to 80๐C).
|
|
Display: 0.42” (10.6 mm) 4 digit LCD
|
|
Response
Time:
1 seconds.
|
|
Power Requirements: 9 volt alkaline battery. Battery included but not connected.
|
|
Weight: 10.2 oz (289 g).
|
|
Connections: Two barbed connections for use
with 1/8” (3.18 mm) or 3/16” (4.76 mm)
I.D. tubing. Two compression fittings for use with 1/8” (3.18
mm) I.D x 1/4” (6.35 mm) O.D. tubing for 477-7-FM & 477-8-FM only.
|
|
Agency
Approvals:
CE and FM, USB models are not FM approved Intrinsically safe.
|
|
Model
Number
|
Range
|
Maximum
Pressure
|
|
|
477-000-FM
|
0-1.000
in w.c.
|
5
psig
|
|
|
477-00-FM
|
0-4.000
in w.c.
|
5
psig
|
|
|
477-0-FM
|
0-10.00
in w.c.
|
5
psig
|
|
|
477-1-FM
|
0-20.00
in w.c.
|
10
psig
|
|
|
477-2-FM
|
0-40.00 in w.c.
|
10 psig
|
|
|
477-3-FM
|
0-200.0
in w.c.
|
30
psig
|
|
|
477-4-FM
|
0-10.00
psi
|
30
psig
|
|
|
477-5-FM
|
0-20.00
psi
|
60
psig
|
|
|
477-6-FM
|
0-30.00
psi
|
60
psig
|
|
|
477-7-FM
|
0-100.0
psi
|
150
psig
|
|
|
477-8-FM
|
0-150.0
psi
|
200
psig
|
|
|
|
|
|
|
|